The Cold Cathode transformer is mid-point grounded with a balanced design. It is best used in heavy duty outdoor non-weatherproof environment. The Cold Cathode transformer is mid-point grounded with a balanced design. It is best used in heavy duty outdoor non-weatherproof environment.  - Recommended for architectural indoor lighting applications.
- Mid-point grounded and balanced design, providing safer operation of your neon sign.
- High power factor models are available, which allows installation of more units on one circuit, saving material and labour costs.
- Low temperature rise, providing lower operating temperature, reducing the probability of heat problems and extending longevity of the installation.
Available Models Cold Cathode Style - Heavy Duty Outdoor Non-Weatherproof Normal Power Factor 120-Volts, 60 Hz | PART No. | VA | LINE AMP | SECONDARY | WT | | | | | kV - mA | lbs | | 9120B120 | 540 | 4.70 | 9 - 120 | 43 | | 75120B120 | 450 | 3.90 | 7.5 - 120 | 39 | | 5120B120 | 300 | 2.60 | 5 - 120 | 35 | | All models above are UL2161 Recognized and CSA Approved Cold Cathode Style - Heavy Duty Outdoor Non-Weatherproof High Power Factor 120-Volts, 60 Hz | PART No. | VA | LINE AMP | SECONDARY | WT | | | | | kV - mA | lbs | | P9120B120 | 1080 | 9.4 | 9 - 120 | 39 | | P75120B120 | 900 | 7.8 | 7.5 - 120 | 35 | | P5120B120 | 600 | 5.2 | 5 - 120 | 32 | | All models above are UL2161 Recognized and CSA Approved | | For product dimensions, click here.
|